Showing posts with label "crawlspace radon". Show all posts
Showing posts with label "crawlspace radon". Show all posts

Saturday, December 17, 2011

Sealing Your Crawlspace

I thought I was finished with radon work for 2011, but I had a follow-up visit to a home where the radon levels have stubbornly remained above 4.0. This time I concentrated on sealing the existing vapor barrier in the crawlspace. After about 4 hours of taping and sealing, I got the vacuum gauge to show a slight increase in suction for my efforts:

Manometer/Vacuum Gauge at the Start 

Sand and gravel helps seal difficult areas around cement pillars

Leftover tile pieces serve to seal the perimeter 

Specialty seam tape for sealing tears and other openings 

Gravel for sealing openings around the water heater 

Bricks circa 1910 seal off the sloppy edges 

A hair-increase in vacuum is actually significant for this size area!

Wednesday, December 7, 2011

Crawlspace Radon

I had to return to a property recently, because our post-radon test showed radon levels in their basement apartment to be about .7 above EPA safe limits, although upstairs levels tested safe. The apartment is next to the large crawlspace, and I was to attempt to dig under the basement concrete slab horizontally, from the crawlspace.

Unfortunately, I could find no gravel layer from the outside, so I have to return again tomorrow, to attempt to drill directly through the concrete floor from inside the apartment to find that gravel layer. If we find that there is no gravel layer, the only alternative will be to install a heat recovery ventilator.
Digging below the foundation 


Nothing but concrete - on dirt 

Current vacuum levels 

Sealing loose sections with sand raised vacuum levels a bit.... 

Our original opening was sealed back up 

Some loose tile helps seal the edges 



Sand is also good for sealing loose edges of the vapor-barrier 

Sand seals around the base of the A/C unit 

A pillar is a leaky spot until we pour sand around it. 

Placed a trim ring around the pipe exit

Thursday, September 29, 2011

HRV Success!

I recently received a passing radon test of 3.9 pCi/L on that large crawlspace job where we installed the heat recovery ventilator back on September 8. Success! To achieve even lower readings I will recommend spray-on insulation for the ceiling.


Thursday, September 22, 2011

Tuesday Radon Job on Wednesday

I finally finished up the Tuesday radon job on Wednesday. I'm not really finished though, until we get the results of the short-term radon test, which usually takes three weeks and means I either have to go back and do more work, or we pass and I get paid the other 50% and am really done. Still thinking about going into the radon business?

Here are some pictures:

Needed this 30 ft ladder for this huge home. This made the height of the roof a non-issue-a very stable ladder!

The outside section, completed

Pipe-cutting area

My electric person is pretty good. Highly recommended...

Steel straps are best for securing the pipe to the house

Belle Meade Section

"Retarder-Tee" for air-tight membrane penetrations

Everything is Hooked Up

 We have good suction under the vapor barrier-goodbye radon gas!

Tuesday, September 20, 2011

Tuesday Radon Job

What I expected was a one-day job has turned into a two-day job. Too many trips for materials today.

Here are the pix from today's experience:

The 250,000 Mile Toyota 4Runner

Nashville Morning Traffic

Crawlspace Entrance

The Problem-Unsealed Plastic Covering the Crawlspace Floor and High Radon in the House Above

 Radon Solution Phase 1 - Seal All Leaks in Plastic Flooring

A Nice, Large Crawlspace Area to Work In...

 Phase 2 - Install Radon Fan and Connect to Pipe Under Plastic Covering
 Phase 2, Step 1: Drill hole in wall for 4" Pipe - Equipment

"This looks like a good spot"

 Dewalt Power

Completed Pipe Entrance to Crawlspace

Oops! Looks like the Ladder is a Bit Wimpy....

The saga continues tomorrow.....

 - Home by twilight -


Thursday, September 8, 2011

Heat Recovery Ventilator

My two years of contract work in Florida having finally ended last week, I managed to land my first radon job in Nashville through a previous client.

This job was a tough call because it is a fairly large crawlspace, which some other firm had already attempted to seal with a plastic liner, but apparently it failed to have any effect on radon levels, possibly because the moisture in the walls prevented any kind of significant sealing of the edges. I could either install a better plastic liner, at a cost of a few thousand dollars and hope I can seal it, or merely install a heat recovery ventilator (air exchanger) for much less. So I installed the HRV.

Here are some pictures, although I forgot to photograph the exit vents. I am anxiously awaiting the results of the post-radon test. Hopefully this does the job. Check back for the results of test #1:

 Actually nice because you can stand up in the center part

 Moisture in the walls does not bode well for long-term sealing

A nice new Fantech HRV with 200 cfm capacity

Monday, June 13, 2011

Stuck on "Pause"

I am now stuck in the Florida panhandle for the foreseeable future, under a "temporary" work contract. Please feel free to email me for radon advice in the meantime, or request referrals to other qualified radon contractors.

I will be sure and delete this blog entry when I am again available for radon work in the Central Tennessee area.

Thanks.

Kurt Anderson
Help4Radon.com

Friday, May 13, 2011

Green Hills Crawlspace

I traveled up to Green Hills today to measure out this crawlspace. Although the owner did a nice job of laying down some thick plastic, radon levels remained unchanged in the living space above. Since radon measured below 15.0 pCi/L, I will propose the installation of a heat recovery ventilator (air exchanger).

Friday, May 6, 2011

Long Term Test Results

Here is the latest long term test result from one of our clients in Columbia, TN from the Spring of 2010. Their original radon level was around 30+ if I recall correctly. I remember this client watched my every move the entire 8 hours or so it took to do the work, and the attic during the last phase of installation was about 110 degrees. It definitely was a job I was hoping we passed the first time. They had scored about 1.5 on the short term test, thankfully, but the recent results from the the long term test (91 days to 12 months) showed even lower radon scores!




Thursday, April 28, 2011

A Beautiful Thing.....

I got the radon test results back from that recent job with the really tight soil-the one with the curious cat?

Anyways I got the radon down to below a .5, super-good results for a house like this. Now I can get paid!!!