Showing posts with label "radon gas". Show all posts
Showing posts with label "radon gas". Show all posts

Saturday, December 17, 2011

Sealing Your Crawlspace

I thought I was finished with radon work for 2011, but I had a follow-up visit to a home where the radon levels have stubbornly remained above 4.0. This time I concentrated on sealing the existing vapor barrier in the crawlspace. After about 4 hours of taping and sealing, I got the vacuum gauge to show a slight increase in suction for my efforts:

Manometer/Vacuum Gauge at the Start 

Sand and gravel helps seal difficult areas around cement pillars

Leftover tile pieces serve to seal the perimeter 

Specialty seam tape for sealing tears and other openings 

Gravel for sealing openings around the water heater 

Bricks circa 1910 seal off the sloppy edges 

A hair-increase in vacuum is actually significant for this size area!

Wednesday, December 7, 2011

Crawlspace Radon

I had to return to a property recently, because our post-radon test showed radon levels in their basement apartment to be about .7 above EPA safe limits, although upstairs levels tested safe. The apartment is next to the large crawlspace, and I was to attempt to dig under the basement concrete slab horizontally, from the crawlspace.

Unfortunately, I could find no gravel layer from the outside, so I have to return again tomorrow, to attempt to drill directly through the concrete floor from inside the apartment to find that gravel layer. If we find that there is no gravel layer, the only alternative will be to install a heat recovery ventilator.
Digging below the foundation 


Nothing but concrete - on dirt 

Current vacuum levels 

Sealing loose sections with sand raised vacuum levels a bit.... 

Our original opening was sealed back up 

Some loose tile helps seal the edges 



Sand is also good for sealing loose edges of the vapor-barrier 

Sand seals around the base of the A/C unit 

A pillar is a leaky spot until we pour sand around it. 

Placed a trim ring around the pipe exit

Wednesday, November 30, 2011

Wasted Wednesday

I traveled up to Goodlettsville today, to install a basic radon mitigation system. Of course I had to do the standard diagnostic testing for adequate airflow under the basement concrete slab before I began installing the main system. In this case the house failed the test, so it was a complete wasted morning-no installation occurred.

I think from now on, I will charge $75.00 for the diagnostic part, applicable towards the original estimate if the house passes the test, otherwise I lose that amount on travel expense and labor.

In this particular case, the concrete was about 10" thick and directly on dirt, so there was no crossflow of air to work with:

 Concrete Basement

 Client wants the pipe to come through the concrete wall to the outside, here.

 Time to christen my new and improved Bosch hammer drill

 The pilot hole from the outside comes through the basement wall at a good spot and luckily not into that black pipe there.

 We'll need a 3 5/8 diameter hole, here.

...But first we have to check beneath the concrete floor for a gravel-layer. X marks the spot. 

"Ready for Radon" 

This time, a 1 inch bit will be needed. 

My small industrial vac with a big motor. 

The work area. 

 So far, 10" of concrete and no sign of gravel. Maybe we're too close to the wall? The new Bosch hammer drill performs amazingly well in concrete and it doesn't try to tear my arm off, unlike the el-cheapo hammer drill I used from 2008 through last month.

5" further in should get us away from the footer. 

This time we hit some hard-packed dirt at about 8", but no gravel to be found. I will recommend a heat recovery ventilator. A subslab ventilation system will likely fail.

Concrete in a tube to patch the test-holes. 

 And some foam backing-rod filler.

We were never here......

I also patched the smaller hole to the outside.

Wasted trip. At least the dog was friendly.

Thursday, September 29, 2011

HRV Success!

I recently received a passing radon test of 3.9 pCi/L on that large crawlspace job where we installed the heat recovery ventilator back on September 8. Success! To achieve even lower readings I will recommend spray-on insulation for the ceiling.


Thursday, September 22, 2011

Tuesday Radon Job on Wednesday

I finally finished up the Tuesday radon job on Wednesday. I'm not really finished though, until we get the results of the short-term radon test, which usually takes three weeks and means I either have to go back and do more work, or we pass and I get paid the other 50% and am really done. Still thinking about going into the radon business?

Here are some pictures:

Needed this 30 ft ladder for this huge home. This made the height of the roof a non-issue-a very stable ladder!

The outside section, completed

Pipe-cutting area

My electric person is pretty good. Highly recommended...

Steel straps are best for securing the pipe to the house

Belle Meade Section

"Retarder-Tee" for air-tight membrane penetrations

Everything is Hooked Up

 We have good suction under the vapor barrier-goodbye radon gas!

Tuesday, September 20, 2011

Tuesday Radon Job

What I expected was a one-day job has turned into a two-day job. Too many trips for materials today.

Here are the pix from today's experience:

The 250,000 Mile Toyota 4Runner

Nashville Morning Traffic

Crawlspace Entrance

The Problem-Unsealed Plastic Covering the Crawlspace Floor and High Radon in the House Above

 Radon Solution Phase 1 - Seal All Leaks in Plastic Flooring

A Nice, Large Crawlspace Area to Work In...

 Phase 2 - Install Radon Fan and Connect to Pipe Under Plastic Covering
 Phase 2, Step 1: Drill hole in wall for 4" Pipe - Equipment

"This looks like a good spot"

 Dewalt Power

Completed Pipe Entrance to Crawlspace

Oops! Looks like the Ladder is a Bit Wimpy....

The saga continues tomorrow.....

 - Home by twilight -